Installing an electric water heater: the rules

Safety valve group, dedicated 20 A circuit, off-peak contactor, fixing: the summary for a compliant cylinder installation.

Chauffe-eau électrique installé avec groupe de sécurité

A water heater is 4 connections that each need to be right: cold water, hot water, safety discharge, electricity. The compliant summary.

The connection diagram

cylindercold water →7-bar safety groupto waste (trap) — dripping during heating is normal→ hot waterdedicated 20 A circuit (2.5 mm²) + off-peak contactor

The rules point by point

  • New 7-bar safety valve group at every cylinder replacement, mounted directly on the cold inlet, connected to a trapped waste — its drip during heating is normal (expansion).
  • Hard water or pressure > 5 bar: add a pressure reducer upstream (set to 3-3.5 bar).
  • Electricity: dedicated 2.5 mm² circuit / 20 A breaker + off-peak contactor to heat at cheap-rate hours.
  • Dielectric unions on the hot side: they block galvanic corrosion between copper and steel.
  • Fixing: a full 200 L cylinder weighs ~250 kg — on plasterboard, through-reinforcement or a floor tripod is mandatory; see fixing heavy loads.
  • In a bathroom: only outside zones 0/1 (or a small protected instant heater in zone 1) — see the zones.

The maintenance that doubles its life

  • Operate the safety group once a month (small knob) against scaling.
  • Anode and tank: check at 4-5 years in hard water; set the thermostat to 55-60 °C (anti-legionella AND anti-scalding).