Plasterboard suspended ceiling: channels, hangers and spacings

Hangers every 1.20 m, channels every 60 cm, boards screwed across: the rules of a suspended ceiling that never cracks.

Ossature de faux plafond suspendu to moitié plaquée

A suspended ceiling hides services, takes recessed lights, insulates from noise above — and goes up in a weekend if you respect three spacings. Here they are, with the diagram.

The spacings that decide everything

Element Max spacing
Hangers 1.20 m along the channel
Furring channels 600 mm (500 mm depending on board orientation)
Drywall screws 300 mm
Perimeter angle fixed every 600 mm to the wall

The diagram (section view)

1.20 m maxexisting floor abovehangersfurring channels — 600 mm centres (perpendicular to the boards)board screwed every 300 mm — wool laid on the frame if insulating

The golden rules

  • Boards fitted perpendicular to the channels, joints staggered by one channel between rows.
  • Never screw boards straight into the joists of an old floor: always the frame, which absorbs movement.
  • Noise from above? Anti-vibration hangers + 100 mm wool + double layer: see our soundproofing guide.
  • Recessed spots: protective covers where they meet the wool, and at least 65 mm of void.

Ceiling closed, on to the joints and then the floors — the full order here.